Maintenance - 500h
ICC1200C-1EN3.pdf2012-05-16
Maintenance - 500h
Park the roller on a level surface.
The engine must be switched off and the
parking brake activated when checking or
adjusting the roller, unless otherwise specified.
Park the roller on a level surface.
The engine must be switched off and the
parking brake activated when checking or
adjusting the roller, unless otherwise specified.
Ensue that there is good ventilation (air
extraction) if the engine is run indoors. Risk of
carbon monoxide poisoning.
Ensue that there is good ventilation (air
extraction) if the engine is run indoors. Risk of
carbon monoxide poisoning.
Drum - oil level
Inspection - filling
Fig. Drum, vibration side
1. Oil plug
2. Inspection hole
21
Run the roller slowly until the oil plug (1) is opposite
one of the inspection holes (2).
Unscrew the plug and check that the oil level reaches
up to the bottom of the hole. Top up with new oil if
necessary. Use oil as per the lubricant specification.
Clean the magnetic oil plug (1) from any metallic
residue, and refit the plug.
83