Operation
34 4812325556EN 2017-11-22
Starting
Screen - Control
Sit down for all operations.
Turn the ignition key (1) to the position I and the initial screen
is shown in the Control panel (2).
Check if the voltmeter (3) appoints at least 24 volt and if the
fuel (4) and water (5) levels show a percentage value.
The hourmeter (6) records and shows the total quantity of the
engine working hours.
1
2
Fig. Side panel
1. Ignition key
2. Control Panel
6
4
5
3
Fig. Status screen
3. Voltmeter
4. Fuel level
5. Water level
6. Hourmeter