Dyness Tower T21 - 2 Product Specifications; System Performance Parameter

Dyness Tower T21
30 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Tower ESS User Manual
©Dyness reserves the copyright of this document.
7
2 Product Specifications
System Performance Parameter
Table 2-1 Tower system parameters
Model
T21
T17
T14
T10
T7
Cell technology
LFP
LFP
LFP
LFP
LFP
Total energy stored
[kWh]
21.31
17.76
14.21
10.66
7.10
Usable energy [kWh]
20.245
16.872
13.499
10.127
6.745
Recommend depth of
discharge
95%
95%
95%
95%
95%
Max depth of discharge
100%
100%
100%
100%
100%
Module configuration
6 series
5 series
4 series
3 series
2 series
Voltage range [V/DC]
504~657
420~547
336~438
252~328
168~219
Battery system voltage
(V/DC)
576
480
384
288
192
Battery system capacity
(Ah)
37
37
37
37
37
Battery system charge
voltage (V/DC)
657
547.5
438
328.5
219
Battery system charge
current [A] (standard)
7.4
7.4
7.4
7.4
7.4
Battery system charge
current [A] (normal)
18.5
18.5
18.5
18.5
18.5
Battery system charge
current [A] (max)
37
37
37
37
37
Battery system discharge
minimum voltage (V/DC)
504
420
336
252
168
Battery system discharge
current [A] (standard)
7.4
7.4
7.4
7.4
7.4
Battery system discharge
current [A] (normal)
18.5
18.5
18.5
18.5
18.5
Battery system discharge
current [A] (max)
37
37
37
37
37
Battery system max
charge & discharge
current [A]
(in communication with
22.5
22.5
22.5
22.5
22.5

Related product manuals