Fitting notes
Service manual
General notes
Disconnect the machine from the electrical outlet at
all times during repair and test. Failure to do so could
result in electric shock or personal injury.
Female terminal clips used in DC23 contain a locking
mechanism. The release pip will need to be activated
before separation from the male terminal can occur.
Protective safety goggles and gloves must be worn when
applying glue.
All screws used in DC23 are Torx T15 unless otherwise
stated.
Cable rewind replacment - removal
Recommended tools to repair DC23:
Torx T-10 and T-15 screwdrivers
Philips screwdriver
Large flat bladed screwdriver
Terminal screwdriver
Long/needle nosed pliers
06
01 Press the cyclone release catch
to remove the cyclone and bin
assemblies from the front of the
product.
Wire colours may vary between territories.