Form 6 triple-single microprocessor-based rack mount recloser control
1INSTALLATION AND OPERATION INSTRUCTIONS MN280084EN July 2018
Product information
Introduction
Service Information MN280084EN provides installation
and operation instructions for the Form 6 Triple-Single
rack mount recloser control.
Refer to the following information as appropriate for your
version of ProView software:
Service Information S280-70-9 Form 6-TS Recloser
Control Programming Guide: ProView 4.X.X software
Service Information S280-70-23 Form 6-TS Recloser
Control Programming Guide: ProView 5.X.X software
The Form 6 Triple-Single (Form 6-TS) control is designed for
use with these reclosers:
NOVA-TS Triple-Single (3) reclosers. Refer to Service
Information MN280045EN NOVA-TS Recloser Installation
and Operation Instructions.
Read this manual first
Read and understand the contents of this manual and follow
all locally approved procedures and safety practices before
installing or operating this equipment.
Additional information
These instructions cannot cover all details or vari ations
in the equipment, procedures, or process described, nor
provide directions for meeting every possible contin gency
during installation, operation, or maintenance. When
additional information is desired to satisfy a problem not
cov ered sufficiently for the user’s purpose, contact your
Eaton representative.
ANSI standards
Eaton Cooper Power series reclosers are designed and
tested in accordance with the following ANSI standards:
C37.60 and C37.85 and ANSI Guide C37.61.
Quality standards
ISO 9001-Certified Quality Management System
Acceptance and initial inspection
Each Form 6-TS recloser control is completely assembled,
tested, and inspected at the factory. It is carefully calibrated,
adjusted and in good condition when accepted by the carrier
for shipment.
Upon receipt, inspect the carton for signs of damage.
Unpack the control and inspect it thoroughly for damage
incurred during shipment. If damage is discovered, file a
claim with the carrier immediately.
Handling and storage
Be careful during handling and storage of the control
to minimize the possibility of damage. If the control is
to be stored for any length of time prior to installation,
provide a clean, dry storage area. If storage is in a
humid atmosphere, make provisions to keep the control
circuitry energized.
Control power
All operating power is obtained from the substation battery
bank. The following power supply option is available and
configured at the factory:
40 VDC –140 VDC Burden 14 Watts
ote:N The 40 VDC – 140 VDC power supply is a universal
power supply adaptable for either 48 VDC or 125 VDC
substation batteries.
Refer to the Customer connections for DC power and
ACvoltagesensing section of this manual for incoming
power wiring illustrations for the Form 6-TS rack mount
recloser control.
Power consumption
Control: 14 W
Total power when operating: 280 W
Power consumption at rest: 24 to 50 W (dependent
upon added control circuit boards

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Eaton Cooper Power Form 6-TS and is the answer not in the manual?

Eaton Cooper Power Form 6-TS Specifications

General IconGeneral
BrandEaton
ModelCooper Power Form 6-TS
CategoryController
LanguageEnglish

Related product manuals