Performance Characteristics
Typical performance with mineral oil at 21 cSt (102 SUS) and at 50_C(122_F)
Pressure drop: free flow through check valve
Internal Leakage Across Closed
Check Valve
Less than 0,25 ml/min (0.015 in
3
/min) at
250 bar (3625 psi)
0
bar
50 6040302010 L/min
0 4 8 12 16 USgpm
0
psi
Flow rate
3
6
9
12
15
18
21
24
27
30
100
200
300
400
Pressure drop
For other viscosities, see “Further
Information”.