EasyManuals Logo

Eaton VICKERS SystemStak User Manual

Eaton VICKERS SystemStak
55 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #29 background imageLoading...
Page #29 background image
4 EATON Vickers Solenoid Operated Directional Valves Product Catalog V-VLDI-MC011-E September 2008
Functional
Symbols
Spool types shown repre-
sent the highest proportion
of market requirements. For
other spool functions that may
be required, consult your
Eaton sales representative.
Solenoids identified to U.S.
standards
Functional symbols related to
solenoid identity A” and/or
“B” according to NFPA/ANSI
standards, i.e. energizing
solenoid A” gives flow P to
A, solenoid “B” gives flow P
to B (as applicable).
FOR
SPOOL
SOLENOID TYPE SOLENOID
B All A
except
“8”
A “8” only B
For valves with type “8”spools,
solenoid identity to U.S.
convention is the same as for
European convention.
Solenoids identified to
European standards
(specify “V” in model code)
Functional symbols related
to solenoid identity A” and/
or “B” according to European
convention i.e. solenoid A
adjacent to A” port, solenoid
“B” adjacent to “B” port of
valve.
For differences in valve func-
tion, refer to Performance
Data page 11.
F build spools.
U.S. solenoid standard
Double solenoid valves,
two position, detented
Single solenoid valves,
solenoid at port A end
Single solenoid valves,
solenoid at port B end
Double solenoid valves,
spring centered
s Transient condition only
s Transient condition only
The valve function schematics apply to both U.S. and European valves.
European solenoid standard
DG4V-3(S)-*N(V)
DG4V-3(S)-*C(V)
DG4V-3(S)-8C(V)
DG4V-3(S)-*A(V)
DG4V-3(S)-*AL(V)
DG4V-3(S)-*B/F(V) DG4V-3(S)-*BL/FL(V)
DG4V-3(S)-8BL(V) DG4V-3(S)-8B(V)
Double solenoid valves,
two position, detented
Single solenoid valves,
solenoid at port A end
Single solenoid valves,
solenoid at port B end
Double solenoid valves,
spring centered
Port A
Port P
Port T
Port B
Solenoid
A
Solenoid
B
Port A
Port P
Port T
Port B
Solenoid Solenoid
P T
A B
B .loS A .loS
P T
A
B
Sol. B
P T
A
B
Sol. A
P T
A B
B .loS A .loS
P T
A B
B .loS A .loS
P T
A
B
Sol. B
P T
A
B
Sol. A
P T
A B
B .loS A .loS
P T
A B
B .loS A .loS
P T
A
B
Sol. B
P T
A
B
Sol. A
P T
A B
B .loS A .loS
P T
A B
B .loS A .loS
P T
A
B
Sol. B
P T
A
B
Sol. A
P T
A B
B .loS A .loS
2 0
2
0
2
22
24
22
24
2 0
2
0
2
22
24
22
24
0
2
6
66
7
33
34
0
2
7
0
2
7
222222
2512525
6516565
33
34
33
34
6
66
6
66
0
2
6
66
7
33
34
0
2
7
0
2
7
222222
2512525
6516565
33
34
33
34
6
66
6
66
0
2
6
66
7
33
34
0
2
7
0
2
7
222222
2512525
6516565
33
34
33
34
6
66
6
66
88
8
88
8
88
8
P T
A B
Sol. A Sol. B
P T
A B
Sol. B
P T
A B
Sol. A
P T
A B
Sol. A Sol. B
P T
A B
Sol. B
P T
A B
Sol. A
P T
A B
Sol. A Sol. B
P T
A B
Sol. B
P T
A B
Sol. A
P T
A B
Sol. A Sol. B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Eaton VICKERS SystemStak and is the answer not in the manual?

Eaton VICKERS SystemStak Specifications

General IconGeneral
BrandEaton
ModelVICKERS SystemStak
CategoryControl Unit
LanguageEnglish

Related product manuals