ECD 100-181 - SP3 - Multi Purpose Output 3; SP4 - Multi Purpose Output 4; TSL - Top Slowing Input; UD - Up;Dn Relay Output

ECD 100-181
75 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
I N P U T S O U T P U T S
SP3 - Multi Purpose Output 3
SP3 RELAY OUTPUT Spare relay output 3
SP3 may be used for Inspection Speed input, depending on DRV setting
SP3 may be used for auxiliary leveling pump operation, depending on DRV setting. See also EEprom settings ALP
See Section 6: Motion, for more on the relay operation
SP4 - Multi Purpose output 4
SP4 RELAY OUTPUT Spare relay output 4
Australia: SP4 relay pulls in when SAF input is active.
On loss of safety circuit (and SAF input), SP4 relay drops out.
SP4 relay contacts may be used to disconnect the door operator from the supply on loss of the safety circuit.
USA: Fire Service Code 17.1. FS EEprom setting must be set to 01
When Fire Recall - Phase 1 activated, SP4 n/o relay contact is used to override the emergency stop switch in the
car.
TSL Top SLowing input
Top floor position correction limit and forced slowdown limit for terminal floor.
TSL LED shall be off when TSL limit is activated.
TSL LED must remain off when lift is at the highest point in the shaft, ie counterweight landed or ram fully
extended
UD - Up/Dn relay output
UD RELAY OUTPUT Com. UP/DN output.
See Section 6: Motion, for more on the relay operation
UF - Up Fast relay output
UF RELAY OUTPUT Up fast output
See Section 6: Motion, for more on the relay operation
UHC - Up Hall Call inputs / outputs
inputs / outputs
Front Doors:
1UF I/O 1
st
floor UP call/tell tale light
2UF I/O 2
nd
floor UP call/tell tale light
3UF I/O 3
rd
floor UP call/tell tale light
4UF I/O 4
th
floor UP call/tell tale light
5UF I/O 5
th
floor UP call/tell tale light
Rear Doors:
1UR I/O 1
st
floor UP call/tell tale light
2UR I/O 2
nd
floor UP call/tell tale light
3UR I/O 3
rd
floor UP call/tell tale light
4UR I/O 4
th
floor UP call/tell tale light
5UR I/O 5
th
floor UP call/tell tale light
UP - Up relay output
UP RELAY OUTPUT Up relay output
See Section 6: Motion, for more on the relay operation