32
8. Install the cover and tighten the screws.
9. Turn the fuel tank cap air vent knob to “OFF” after the engine has
completely cooled down.
8.2 Engine
Perform the following steps to protect the cylinder, piston ring, etc. from
corrosion.
1. Remove the spark plug, pour about one tablespoon of SAE 10W-30 into
the spark plug hole and reinstall the spark plug. Recoil start the engine by
walls with oil.
2. Pull the recoil starter until you feel compression. Then stop pulling. (This
prevents the cylinder and valves from rusting).
3. Clean exterior of the generator. Store the generator in a dry, well-ventilated
place, with the cover placed over it.
9. TROUBLESHOOTING
9.1 Engine won’t start
1. Fuel systems
No fuel supplied to combustion chamber.
• No fuel in tank…Supply fuel.
• Fuel in tank….Fuel tank cap air vent knob and fuel cock knob to “ON”
•
• Clogged carburetor…. Clean carburetor.
2. Engine oil system
• Oil level is low…. Add engine oil.
3 . Electrical systems
• Put the 3-in-1 switch to “CHOKE” and pull the recoil starter … Poor spark.
• Spark plug dirty with carbon or wet … Remove carbon or wipe spark plug dry.
• Faulty ignition system … consult our company authorized dealer.
TROUBLESHOOTING
9.2 Generator won’t produce power
• Safety device (DC protector) to “OFF”…. Press the DC protector to “ON”.
•