Restart Cleaning Module:
T
o restart the cleaning module, press keys 1,2 and 4 for seven seconds.
4.5.1 Alarm - Water valve
If the mixing container will be filled at beverage mode, a slashed faucet symbol is
displayed and the display will flash between green and blue.
If there is a active fault message a further slashed faucet is displayed the display will flash
between red and blue.
Fig. 26: Alarm - Water valve
4.5.2 Alarm - Alarm - Error: Compressor
Fig. 27: Alarm level - ERROR: Compressor
1 Current consumption to high at start.
2 Compressor runs continuously for 15 min.
3 Compressor running time higher than 75 % in one hour.
See
Ä
Chapter 6.2.1 ‘Display error messages and incidents’ on page 32, Fig. 33.
4.5.3 Alarm - No Cleaning
If the ‘Beer Cut’ time is exceeded, an alarm is displayed and the ‘Beer Cut’ activated.
Cleaning must be carried out.
Fig. 28: Alarm level - No Cleaning for 21 days
Control / Visualisation
28Rev. 04-06.2018