23
8.5. Trouble shooting and remedy
Fault Cause Remedy
The unit does
not start
•
• Error message in display
•
•
•
•
No pressure /
too low pressure
• Insufficient water supply at unit
• Filter is clogged
•
sounds
•
• Defect in booster unit for satellite
• No water supply
•
• Clean the filter
• Call technician
• Place rinsing nozzle
• Consult direction for use for booster unit
• Ensure water supply
Insufficient foam
creation
• Product not suitable
• Insufficient air supply at unit
• Air pressure in mixing chamber too high
•
• Incorrect nozzle
•
• System needs deliming
• Choose suitable product
•
•
•
• Place foam nozzle 50/200
•
•
No foam
creation
• Product not suitable
• Air pressure in mixing chamber too high
•
• No air supply at unit
•
•
•
• System needs deliming
• Choose suitable product
•
•
• Ensure air supply
•
• Clean nozzle
•
•
No spray
sanitising
•
•
•
• System needs deliming
•
• Clean nozzle
•
•
8.6. Service address