ecom-B
After storing the CO-values the next point
are the draught measurements (curser key
<down>). For exact measuring it’s recom-
mended to reset the sensor to zero. Re-
move the draught hose off the instrument
and press <CAL>. The zero point of the
sensor is set now. After the draught has
stabilised it can be stored for later printout
by pressing the key <store>:
At the end of the measurement routine
(curser down) it is checked whether a gas
leakage at the unit could be determined.
Confirmation could be done by using the
key <Enter> (yes / no).
The printout (IR printer required) of all re-
sults of the measurement routine could be
done by pressing <Print>.
Atmosph. boiler
Draft
-0.04 hPa
Val.: -0.04 hPa
Set zero point
CAL.
Atmosph. boiler
Gas leakage
No
Change: