63
inserting the end of an opened paper-clip into the reset hole (see
manual for WS68 and WS69 array) or pressing the reset button
(WS80, WS85 and WS90 array) for about five seconds will
restart the array firmware and the LED will start blinking again
(WS68/69 every 16 seconds, WS80 every 5 seconds, WS85/90
every 9 seconds).
If A doesn’t provide the desired result, we have to perform a
hardware rest.
B: hardware reset
- take out the backup batteries
- cover the solar panel of the array tightly with black tape or take
it into a dark room and wait until the LED stops burning or
blinking. The internal battery has to be discharged completely.
This may take up to 48 hours.
- once the LED has stopped blinking, re-insert the batteries.
- the array should power-up and start blinking again every 5-16
seconds depending on the array model.
9 Rain gauge reports rain when it is not raining