product operating instruction
E.G.O. Germany (E.G.O. Elektro-Gerätebau GmbH)
document id.: 90.60160.286-001-04-A / state: 230 - released
designation: Induction Gx
2.4.5 High voltage
The Induction generator may be damaged previously if the high voltage is applied directly in full
amount.
Only use high voltage testers which are electronically controlled und apply the high voltage
in a ramp.
2.4.6 Damage of contacts
Pollution on contacts (e.g., by touching them with dirty hands) could lead to damaged contacts or
contact problems.
Make sure that the contact areas are not polluted (e.g., by corrosion supporting substances).
2.4.7 EMC problems
A wrong cable routing or too long wires may cause EMC problems (interconnecting cable of
generators).
Perform the cable routing as recommended in the operating instruction and customer
documentation.
2.4.8 Wrong storage or transportation
A wrong storage, packaging or transportation can damage induction products.
Do storage and transportation as recommended in chapter 3.