5 Cleaning and maintenance
5.1 Cleaning
In the final appliance the Gx induction is not accessible for the end user, because it is mounted under a
glass ceramic surface. Therefore, Gx induction must not be cleaned.
5.2 Maintenance and repair
NOTICE! On repair measurements allowed by E.G.O. may be performed by the customer. Any work on
unpacked PCB’s must be carried out by trained personnel who know how to handle devices that are
sensitive to electrostatic discharges (ESD). Re-soldering PCB’s or the replacement of single electronic
components is generally not allowed.
Gx Induction does not need periodical maintenance. If there are customer complaints considering poor
performance, following checks can be performed:
Proper mounting of the cooktop (e.g., especially good ventilation).
Unsuitable cookware can have a significant influence on the performance.
Induction Gx can be repaired related to defined components. Spare part kits with replaceable
components are available for use during service. Spare parts of similar variants can vary because of
different equipment. Spare parts are mainly ordered as individual parts or as a kit and could be
packaged for transport as a package.
The following components are offered as spare parts:
Power board kit
Filter board kit
Inductors
User interfaces
Fan
Precondition 1
Error code is displayed on the user interface.
Check error code list and suitable repair procedure for affected component in chapter 5.3.
Check and consider further information for replacement in this operating instruction.