Operating Instruction
High Pressure Cleaner cold water, mobile
Series 3x3
3 Product information
Device version Standard and Premium
KD623 UK KD823 UK
Residual current circuit breaker
(max. allowed residual current)
mA 30 30
Extension cable up to 20 m Wires 3 x 3 x
mm
2
2,5 2,5
Water connection
Max. feed pressure bar 5 5
MPA 0,5 0,5
Max. feed temperature ° C 45 45
Minimum feed volume l/min 15 15
Suction height m 0 0
Performance data device
Nozzle size --- 035 050
Operating pressure bar 30 - 135 30 - 125
MPA 3 - 13,5 3 - 12,5
Max. operating over-pressure bar 150 140
MPA 15 14
Discharge capacity l/h 300 - 600 300 - 720
Recoil force
trigger gun
N 29,8 33,5
Pump speed rpm 1400 1400
Dimensions and weights
Length
Standard (with packaging)
Premium (with packaging)
mm
mm
805 (790)
830 (790)
805 (790)
830 (790)
Width (with packaging) mm 485 (595) 485 (595)
Height (with packaging) mm 950 (810) 950 (810)
Weight
Standard (with packaging)
Premium (with packaging)
kg
kg
46 (66)
50 (70)
51,8 (71,8)
55,8 (75,8)
Lubricant
Amount of oil l 0,5 0,5
Oil grade type 5W30 5W30
Table 3 - 2 Technical data for High Pressure Cleaner cold water, mobile - Series 3x3