EasyManua.ls Logo

ElanCity EVOLIS - 5.4 POWER SUPPLY

ElanCity EVOLIS
46 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Guide
Product: Evolis
Document REF:
MIU
-
5100
-
A_Evolis Solution GB elancity
Page
13
/
46
Date: 03/01/2018
Confidential document, property of ELANCITY. All copies and transfers are unauthorized without prior consent.
5.4 POWER SUPPLY
Power source:
The Evolis is 12V powered and designed to operate with either:
- Mains: A connection to a permanent mains network. OR to street lighting network in
combination with a battery (12V/22Ah).
- Solar: A solar panel and 2 batteries (12V22Ah).
- Mains Mobile: Battery operated (12V22Ah). Pack includes 4 batteries in total and an
external 12V/4A charger. NOTE: the casing can hold two batteries at one time.
Power consumption:
Thanks to its low power consumption, the battery charging cycle guarantees an extended
duration of operation. Average consumption and wattage as follows:
- Speed: 0.3 A (3.6 Watts at 12V).
- Speed + Message: 0.8 A (9.6 Watts at 12V).
- Standby: 0.1 A (1.2 Watts at 12V).
Power safety / security:
If and when the Evolis radar runs out of power, it has a built-in safeguard that is based on
various thresholds of the battery voltage.
- At 11.5V: The message display wil be de-activated
- At 11.3V: The speed display will be deactivated. The radar will display a small square
to indicate that the speed display is off. NOTE: the radar will still continue to collect
traffic data.
- At 11.1V: The radar will shut down in order to avoid damaging to the battery
Electrical fuse:
To protect the device in case of reversed polarity, a 6.3A fuse is located within the casing.