General IconGeneral
Frequency Response20Hz - 20kHz (+0/-0.5dB)
Total Harmonic Distortion<0.03% (20Hz - 20kHz at full power)
Signal-to-Noise Ratio>105dB (A-weighted)
Input Sensitivity1.1V RMS for full output
Damping Factor>200 @ 8Ω
Input Impedance10 k ohms balanced
ProtectionShort circuit, thermal overload, DC voltage
ConnectorsInputs: XLR balanced, Outputs: Binding posts
Dimensions (H x W x D)483mm
Power Requirements50/60 Hz

Summary

ELECTRICAL

PROTECTION SYSTEMS

Load Protection Circuitry

Description of circuitry protecting speaker loads from transients and DC.

Amplifier Protection Circuitry

Details on the 7300A's current-limiting and thermal protection mechanisms.

OPERATION

Dual Mode of Operation

Instructions for operating the 7300A amplifier in independent dual channel mode.

Bridge Mode of Operation

Instructions for operating the 7300A amplifier in bridged mono mode.

IN CASE OF PROBLEMS

SPECIFICATIONS

SERVICE INFORMATION

Trimpot Adjustments

Overview of trimpots and their adjustment for optimal amplifier performance.

Adjusting R39, the LF Cancel Trimpot

Procedure for adjusting the LF Cancel trimpot (R39) to minimize ripple distortion.

Adjusting R26, the BIAS Trimpot

Procedure for adjusting the BIAS trimpot (R26) to set proper bias level.

Adjusting R23 and R24, Current Limit Trimpots

Procedure for adjusting current limit trimpots (R23/R24) for symmetrical clipping.