System status
Normal
Figure 5.3: Normal system status home screen with Bluetooth® status
1. LEVEL – Indicates the master gain of the system in dB. The range is from mute to +10 dB,
in 1 dB increments.
2. IN1 – VU meter displays the signal level of INPUT 1 into the amplifier INPUT 1 XLR
connector. IN1 and IN2 are independent of each other.
3. IN2 – VU meter displays the signal level of INPUT 2 into the amplifier INPUT 2 XLR
connector. IN1 and IN2 are independent of each other.
4. C - Control app; the available options are:
OFF - DISABLED
FLASHING - PAIRING MODE
SOLID - CONNECTED
5. 1 - Indicates the selected preset number. There are five user defined presents available.
6. E - Indicates the preset is not saved. When the preset is saved the E is not displayed.
Notice!
Bluetooth® is available in select countries.
Contact your nearest Electro-Voice dealer or Electro-Voice distributor for more information.
System protection
System protection limiters indicate when a system is exceeding recommended usage by
indicating CLIP or LIMIT on the LCD display.
CLIP
Figure 5.4: Clipping system status
CLIP indicates the signal to the loudspeaker is too high, resulting in a clipped signal into the
loudspeaker. If CLIP is shown, reduce the input gain knob and/or the signal on the mixer or
source equipment.
LIMIT
OR
Figure 5.5: Limit system status