Next to controlling and monitoring, the RCM-24 Remote Control module provides comprehensive signal
processing functions. It includes a total of 20 parametric lter–, X-over functions, delays, routing and
level control as well as compressors and limiters per channel. All parameters can be freely edited and
stored in the module’s 8 user presets. Independent from network control all DSP-settings ( lter, delay,
level) are maintained in case of failure. Additionally, the control inputs of the power amps can be used
for network-independent switching to another preset (e.g. alarm settings with maximum energy for voice
and text announcements). Therefore, P-Series amps with RCM-24 modules installed ful l even the
highest safety requirements.
When designing the RCM-24, uncompromising audio quality was the highest maxim. AD/DA-conversion
is performed at a resolution of 24-bit and 128-times oversampling with linear phase; the internal word
length is 48 bits. With this the RCM-24‘s dynamic range reaches 115 dB, which is an absolute peak
value for digital audio appliances.
All con guration, control and monitoring details of P-Series power amps are explained in the
documentation accompanying the PC Windows software IRIS.
Carefully open the packaging and take out the power ampli er. Next to the power ampli er itself, the
package also includes this owner’s manual, a mains cord, the warranty certi cate, four stand-feet, six
screw-on connectors (1x 2-pole, 4x 3-pole, 1x 6-pole) plus a set of rack shelf mounting adapters. Please
inspect carefully whether all information in the warranty certi cate has been lled in completely, since
only a completely lled in warranty certi cate entitles you to stake any warranty claims. The appliance
comes with a 36 months warranty, starting with the date when receiving the good from your dealer.
Generally, installing or mounting power amps should be carried out in a way that guarantees continuously
unopposed front-to-rear air circulation. When including an appliance in a closed cabinet or rack shelf
system make sure to provide suf cient ventilation. Leave a gap of at least 60mm x 330mm (up to the
cabinet’s top ventilation louvers) for air circulation between the rear of the power ampli er and the
cabinet’s/rack’s rear wall. Make sure to leave at least 100mm of space above the cabinet or rack shelf
system. Since the temperature inside of the cabinet or rack shelf system can easily rise up to 40°C
during operation, bearing in mind the maximally allowable environmental temperature during operation
for all other appliances installed in the same rack shelf system is mandatory. (also refer to “MAINS
OPERATION & RESULTING TEMPERATURE”)
The use of rails or optionally available rack
adapters – NRS 90235 (112733) – is
mandatory as well when installing the
appliance in a rack shelf system to prevent
the front panel from bending.
For problem-free operation exceeding the maximally allowable environmental
temperature or +40°C is not permissible.
The power ampli er has to be protected against: dripping or splashing water, direct sunlight, high
temperatures or direct in uence of heat sources, high humidity, extensive dust and vibrations.
Condensation on internal parts may occur after transporting the power ampli er from a cold into a
warmer environment. In that case operation is only permissible after the appliance has gained the
new temperature (after approximately one hour). If foreign objects or liquids have entered the power
ampli er’s enclosure make sure to instantly separate the appliance from the mains power and contact
an authorised DYNACORD service centre for inspection before continuing operation.
Do not use any sprays or solvents for cleaning the appliance, because they might severely damage the
surface of the enclosure or lead to dangerous re hazard.