RS-232 INTERFACE
The RS-232 interface is for connecting media control systems as
well
as building management systems providing control and monitoring of all
parameters. Communication is established via an easily to implement ASCII-
protocol allowing trouble-free integration of Remote Ampli ers in media and
touch panel control systems. For a programmer’s guide and complete protocol description, please refer
to the documentation accompanying the IRIS software
.
ADDRESS
The address selection switch allows setting the ampli er’s network address,
which, within a CAN-network, can range from 01 to 250 (FA hex). Caution:
Each address may exist only once within a network. Otherwise network
con icts might occur. Address setting has to be performed in hexadecimal
code. The selection switch LOW represents the low-value digit while the
HIGH-switch represents the high-value digit
.
Adress-Table:
HIGH
LOW
Adress
HIGH
LOW
Adress
0
0
Stand-alone
8
0 ... F
128 ... 143
0
1 ... F
1 ... 15
9
0 ... F
144 ... 159
1
0 ... F
16 ... 31
A
0 ... F
160 ... 175
2
0 ... F
32 ... 47
B
0 ... F
176 ... 191
3
0 ... F
48 ... 63
C
0 ... F
192 ... 207
4
0 ... F
64 ... 79
D
0 ... F
208 ... 223
5
0 ... F
80 ... 95
E
0 ... F
224 ... 239
6
0 ... F
96 ... 111
F
0 ... A
240 ... 250
7
0 ... F
112 ... 127
F
B ... F
reserved
Address 0 (00 hex, factory-pre-set) ensures that the ampli er is separated from the remote
communication, so that it does not appear in the system set-up even though it might be connected to
the CAN-bus. When the ampli er is powered-on with its address set to “0”, all internal parameters are set
to “0” respectively to bypass and the routing is set to 2-in-2. In that case the ampli er behaves absolutely
linear, i.e. signal processing is deactivated
.
REMOTE CAN BUS
Each ampli er employs two RJ-45 sockets for Remote CAN-bus connection.
The sockets are parallel connected and serve as input as well as for
connecting through of the Remote network. Common RJ-45 patch cables
can be used for rack-shelf cabling. The CAN-bus needs to be terminated at
both ends using a 120ohms termination plug.
Detailed guidelines concerning cabling and bus length are provided in the
chapter “REMOTE CONTROL NETWORK”.
Both RJ-45 sockets additionally carry the balanced audio monitor signal. The nominal output level is
+6dBu (1.55V) while the maximum output level is +21dBu (8.7V).
Connector Pin-Assignment:
(
Connector Pin-Assignment:
)
touch panel control systems. For a programmer’s guide and complete protocol description, please refer
(
Connector Pin-Assignment:
)

Other manuals for Electro-Voice Precision P1200RL

Related product manuals