EasyManuals Logo

Electrolux FGCD2456QW User Manual

Electrolux FGCD2456QW
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
13
point, and then the cycle is suspended
Time limit set: 8 sec.
i52” – code: WP BLDC motor
abnormal high current detected
Hardware supervising – will be set when
abnormal high current of about 1.3 amps are
detected.
i53” – code: WP BLDC motor – over
current
Error will be set when the max. allowed current
will be detected higher than the max allowed
current of 1.0 A.
i54” – code: WP will not follow/ rotor
is locked
Error will be set when the motor locked condition
is detected during start of motor and also during
the running motor; reasons can be dirt, too high
load, mechanical problems on impeller.
i55” – code: DC Link overvoltage
Error is set when the DC Link voltage on power
control board is greater than 392 V DC and will
be cleared when dropping under 390 V DC.
i56” – code: DC Link under voltage
Error is set when the Vbat voltage on motor
control board will be detected lower than 225 V
DC and will be cleared if voltage is greater than
260 V DC.
i57“ – code: MCB Vbat voltage
plausibility / ADC Fault
Error will be set if the difference between current
samples are less than 0.03363 [A] for 0.5s.
i58“ – code: WP motor plug
connection
Error will be set if motor connection is detected
wrong based on motor currents measurements. If
currents are inside the thresholds (+/- 21 mA); de-
bounce is set to 1.5 seconds
This code is also possible if a phase is detached
or if a winding inside the motor is broken.
i59“– code: WP current read ADC -
fault
Error is set if there is detected a fault in the current
reading chain on MCB; incl. ADC conversion
It is verified by the current sum of the three motor
phases which should be nearly zero; if the sum is
higher than 40mA for longer than 300 ms than the
assumption is that something is wrong.
i5A“– code: Over temperature or
Overload
Error is set if load is 0.68 A for 10 s for the wash
pump or 0.55 A for 10 s for the drain pump.
i5B“– code: WP/DP current plausibility
Error is set if currents are not changing within 2.5 s
with less than 0.0275 A for WP
Error is set if currents are not changing within 0.5 s
with less than 0.03363 A for DP.
i5C“– code: DP BLDC motor
abnormal high current detected
Hardware supervising – will be set when
abnormal high current of about 0.7 amps are
detected.
i5D“– code: DP BLDC motor – high
current SW
Error will be set when the maximum allowed
current will be detected higher than the maximum
allowed current of 0.550 A.
i5E“– code: DP will not follow/ rotor is
locked
Error will be set when the motor blocked condition
is detected during start of motor and also during
the running motor; reasons can be dirt, too high
load, mechanical problems on impeller.