Installation - electric, steam and gas heating
Technical data, type 500/50
Heating Electric Steam Gas
Drum volume: 528 litres 528 litres 528 litres
Weight: Net 355 kg 355 kg 332 kg
783 lb 783 lb 732 lb
Drum: Diameter 913 mm 913 mm 913 mm
Depth 812 mm 812 mm 812 mm
Revolutions per minute 40 rpm 40 rpm 40 rpm
G-factor 0.8 0.8 0.8
Capacity: 22.7 kg 22.7 kg 22.7 kg
50 lb 50 lb 50 lb
Motor: Effect 2 x 0.37 kW 2 x 0.37 kW
Revolutions per minute 50 Hz 1400 rpm 1400 rpm
Revolutions per minute 60 Hz 1680 rpm 1680 rpm
Effect of drum motor 0.37 kW
Effect of fan motor 0.37 kW
Drum motor- revolutions 50 Hz 1400 rpm
Drum motor- revolutions 60 Hz 1680 rpm
Fan motor - revolutions 50 Hz 1400 rpm
Fan motor - revolutions 60 Hz 1680 rpm
Heat effect: Electric heating 24.0 kW
Electric heating 30.0 kW
Gas heating 40.0 kW
Air consumption:Electric 24.0 kW 840 m
3
/h
Electric 30.0 kW 1060 m
3
/h
Steam 1380 m
3
/h
Gas 1160 m
3
/h
Pipe connection: Evacuation Ø 200 Ø 200 Ø 200
Steam: ISO 7/1-Rp 3/4
Condensate outlet: ISO 7/1-Rp 3/4
Steam: Recommended pressure (absolute) 100-1000 kPa
Max. allowable pressure 1000 kPa
Drop in pressure:Evacuation
Gas pipe connection: ISO 7/1 - R1/2
Gas pressure:
Noise level: < 70 dB (A) < 70 dB (A) < 70 dB (A)
max.
200 Pa
max.
200 Pa
max.
60 Pa
See page regarding pressure
Variable, depen-
dent upon
steam pressure
487 18 39 01 - 300/500/750 - GB
29