Parameter programming
46
487 18 39 01 - 300/500/750 - GB
Count down
SP = Parameter Programming
Count up
Clock button:
Shift between different parameters
Control panel function in Programming mode
00.
Machine type
01.-03.
Temperature
04.
Temperature hysteresis
05.
Time interval
06.
Max. running time or “coin 2”
07.
Running time between reversals
08.
Cooling time
09.-11.
Residual moisture levels
12.-14.
Extra drying time
Adjustable parameters:
Change of machine type
Press the clock button; the display will read
00
.,
which is the first parameter (first parameter
00.
=
machine type).
The parameter numbers are shown for two seconds
with a dot after the last digit.
After two seconds the machine type selected will be
displayed. Example
10
corresponds to manual time
control without reversing.
continues overleaf