EasyManua.ls Logo

Electrolux TT300 - Gas Installation Test Run and Verification; Changing Gas Type (Natural;Bottled)

Electrolux TT300
53 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
487 18 39 01 - 300/500/750 - GB
Installation - gas heating
Gas installation
Test run
Connect a manometer to the measuring branch (2).
(See page regarding gas valves.)
Select a program that uses heat.
Start the machine.
Check the nozzle pressure, see table.
If necessary, adjust the setting screw (4) of the regu-
lator under nipple (3).
Check that the gas is burning evenly and with a
bluish flame.
After testing, prepare the machine for use.
Changing to natural gas/ bottled gas
Mount the supplied nozzle (1); see table.
Connect a manometer to measuring branch (2).
(See gas valve pages.)
Select a program that uses heat.
Start the machine.
Set the nozzle pressure using adjusting screw (4)
under nipple (3).
Check that the gas is burning evenly and with a
bluish flame.
Fit the nipple (3).
After testing, prepare the machine for use.