74
Troubleshooting
11:5WATERHIGHTEMP
Thiserrorcodeisshownifthetemperaturearoundthetemperaturesensorexceeds+98°C/208°F
MaximumallowedtemperatureisdenedinCong.2parameterMAXPROGTEMP.
Possiblecauses:
Suchhightemperaturemeansthattheresistanceinthesensorislowerthanapproximately350Ω.
Thiscanbecausedbyforexampleashortcircuitinthesensor,breakinthecabletothesensor,etc.
Recommendedactions:
1.Measureresistanceintemperaturesensor.Theresistanceshouldbeasshowninthetable
below:
Temp-Resistance
15°C/59°F-7.6kΩ
20°C/68°F-6.0kΩ
25°C/77°F-4.8kΩ
MonitoraprogrambyusingProcessviewerinELSCommonServiceT ooltodetectintermittent
errors.
11:6WATERINMACHINE
Thiserrorcodewillonlyappearatprogramend.
Errorisactivatedifthelevelsystemhasnotindicated“emptydrum”withinacertaintime,typically
3minutes.
Thiserrorcodecanalsoariseiftheprogramisrapidadvancedtotheend,orifprogramisaborted.
MaximumalloweddraintimecanbechangedinCong.2parameterMAXDRAINTIME.
LevelforemptydrumisdenedinCong.2parameterLEVELEMPTY.
ThiserrormessagecanbeturnedoffinConguration-Errorcode.
Possiblecauses:
•Cloggeddrain
•Foam/cloggeddrainpipe
•Incorrectinstallationofdrainpipe/drainsystem
•Defectdrainvalve
•Openwatervalve,llingwater
Recommendedactions:
1.Checkdrainfordirt.
2.Blowthroughthelevelhoseandcheckthatitisnotblockedanddoesnotcontainanywater.
3.Checkintheserviceprogramthatthelevelcontrolisworkingcorrectly.
4.Checkfordetergentoverdosing/remainsoffoam.
5.Makesuretheinstallationofthedrainsystemfollowstheinstallationmanualforthemachine.
6.MonitoraprogrambyusingProcessviewerinELSCommonServiceTool.