84
Troubleshooting
12:11DRYINGERRORWITHRMCPROGRAM
TheerrorcodeisshowniftheanaloginputRMCdoesnotregistertheSTOPVALUEFORRMC
PROGRAMreachedwithinthemaximumdryingtime(normally90minutes).Whentheerroris
triggedthemachinewillautomaticallygotothecoolingmodulebeforetheprogramends.
Theerrorcodeisresetfromthecontrolsystembyashortpressonthecontrolknob/startbutton.
Alongpressonthecontrolknob/startbuttonwillmakethecontrolsystemresetandongoing
programwillbeended.Iftheclothesarestillwetaftermaximumdryingtimeandthedryerisnot
overloaded,checkthattheheatingsystemisworkingcorrectbyusingtheACTIVATEOUTPUTS
menuwhenthemachineisinservicemode.
Note!
Makesurethatthefanisactivebeforeturningontheheat.
Iftheclothesaredry,checktheRMCsystemandharness,connectorsandfunctionsbyreadingthe
electricalschematicandbyusingtheSHOWINPUTSmenuwhenthemachineisinservicemode.
•RMCvaluenoload=0%
•RMCvalue100KOhmbetweenlifteranddrum=~24%(Puttingyourhandoverthelifterontothe
drumwillresultinapproximately20%RMCvalue)
•RMCvaluesystemshortcircuit=50%
12:12DRYINGERRORWITHAUTOSTOPPROGRAM
TheerrorcodeisshowniftheanaloginputOULETAIRTEMP(NTC)doesnotregistertheSTOP
VALUEFORAUTOSTOPPROGRAMreachedwithinthemaximumdryingtime(normally90
minutes).
Whentheerroristriggedthemachinewillautomaticallygotothecoolingmodulebeforethe
programends.
Theerrorcodeisresetfromthecontrolsystembyashortpressonthecontrolknob/startbutton.
Alongpressonthecontrolknob/startbuttonwillmakethecontrolsystemresetandongoing
programwillbeended.
Iftheclothesarestillwetaftermaximumdryingtimeandthedryerisnotoverloaded,checkthatthe
heatingsystemisworkingcorrectbyusingtheACTIVATEOUTPUTSmenuwhenthemachineis
inservicemode.
Note!
Makesurethatthefanisactivebeforeturningontheheat.
Iftheclothesaredry,checktheoutletairsensorandharness,connectorsandfunctionsbyreading
theelectricalschematicandbyusingtheSHOWINPUTSmenuwhenthemachineisinservicemode.
12:13DRYINGERRORWITHTIMEPROGRAM
Theerrorcodeisshownifatimeprogramhascontinuedlongerthanthemaximumdryingtime
(normally90minutes)withoutthedoorhasbeenopened.
Whentheerroristriggedthemachinewillautomaticallygotothecoolingmodulebeforethe
programends.
Theerrorcodeisresetfromthecontrolsystembyashortpressonthecontrolknob/startbutton.
Alongpressonthecontrolknob/startbuttonwillmakethecontrolsystemresetandongoing
programwillbeended.