THE DISPENSING GROUP DOES NOT HEAT SUFFICIENTLY (C12 ITA)
It is possible that after a failure in the heating system of the dispensing group, with conse-
quent overheating, the electrical protection of the dispensing group resistance, may have
occurred.
The electrical protection of the heating element must be replaced, only after removing
the cause of the fault . (questa riga andrà in rosso)
Contact Technical Assistance.
WATER DOES NOT COME OUT OF THE DISPENSING GROUPA(C7 ITA)
Possible causes can be:
- Coffee grinding too fine: adjust it.
- Fault or obstruction to the passage of water in some parts:
contact Technical Assistance.
BREWING PRESSURE NOT BETWEEN 8 AND 9 BAR (C14 ITA)
Unless this value exceeds 1.2 MPa (12 Bar), in which case switch off the machine
and contact Technical Assistance, this is a fault that does not negatively affect the use
of the machine.
The most likely causes are that the pump is out of calibration or worn.
Contact Technical Assistance.
5
6
7
STEAM DOES NOT COME OUT OF THE WAND WHEN THE MACHINE IS HOT
This problem normally arises after the machine has been switched on from cold and is due
to the sticking of the vacuum break valve of the boiler; this does not negatively affect the
use of the machine, in fact:
- after venting all the air activating a dispenser steam wait until the machine
heats up normally and use it.
In the meantime, contact Technical Assistance.
3
WATER COMES OUT OF THE STEAM WAND (C4 ITA =)
This means that the boiler is completely full of water instead of containing a certain quantity
of steam. The possible causes of this are:
- fault in the boiler water inlet solenoid valve;
- electrically isolating incrustation on the level probe or interruption in its electrical connection.
Switch off the machine, turn off the water supply and contact Technical Assistance .