IMPORTANT INSTALLATION NOTES
Flexi flue must be fully extended to length. 5m for exhaust
flue and 2 x 7m for inlet.
5m of flexi flue on the exhaust side MUST be used before
prior to converting to polypropylene. Failure to do this will
result in appliance shutdown.
Air intake pipe - Intake pipe connection to
appliance
Air intake pipe - Intake pipe joiner connection
Cut flue to length to suit
connection.
Ensure ends are burr free
and round, test fit flue will
fit over connection.
Recommended Silicon – Non-acetic, neutral cure
150degc or higher temperature rated.
Bostik RTV 926 or similar.
Apply an 8mm thick silicon
bead fully around heater
connection approx. 10mm
from the top.
Flexi flue is in 7m lengths. A
maximum of 2 lengths can
be used.
Apply an 8mm silicon
bead fully around the
inside of the flue end
(heater connection end)
Fit flue clamp over flue
(loosely).
Slide flue onto connection
spigot fully.
Tighten clamp fully.
Wipe excess silicon,
visually check connection
to ensure connection is
fully sealed