OPTIMA SL255
Digital entry phone panels
OPTIMA SL255
Installation and software manual for fitters
V.3.411
Rev. 14
© 2016 ELFON

Table of Contents

Questions and Answers

  • P
    Patty Lynch DVMAug 13, 2025
    What to do if my ELFON OPTIMA SL255 panel displays 'SHORT.LINE.' message?
    • T
      Trevor MilesAug 13, 2025
      If the ELFON Intercom System panel displays the message "SHORT.LINE.", it indicates a shorted handsets line. To resolve this, eliminate the short-circuit. After correcting the shorting issue, the panel may continue to display the shorting message for up to 10 seconds.
  • J
    James CruzAug 16, 2025
    Why doesn't the code or RFID tag open the electric lock on my ELFON OPTIMA SL255?
    • M
      Mary PerezAug 16, 2025
      If the general/individual code or RFID tag isn't opening the electric lock on your ELFON Intercom System, even without error messages, verify that the permission to open the electric lock using the general/individual code or RFID code is properly configured.
  • C
    castroterriAug 20, 2025
    How to fix power grid hum during calls on my ELFON OPTIMA SL255?
    • A
      aaronhortonAug 21, 2025
      If you hear a power grid hum during a conversation using the ELFON Intercom System, try the following: Increase the supply voltage (do not exceed 15VAC), increase the cross-sections of long supply cables, or increase the power of the central unit power supply if it's too low.
  • S
    stephanieparkAug 25, 2025
    How to stop the peep sound on my ELFON OPTIMA SL255 Intercom System?
    • J
      John HunterAug 25, 2025
      If you are experiencing a peep sound during talking or when putting down the handset receiver on your ELFON Intercom System, first reduce the sensitivity of the panel microphone (using the MICROPHONE potentiometer) or reduce the panel loudness (using the LOUDNESS potentiometer). For specific handsets, try adjusting the handset potentiometer (if available) or setting the balance (BALANCE potentiometer).
  • S
    Shawna ObrienAug 28, 2025
    Why is handset No 1 dialled when dialing other handsets on my ELFON Intercom System?
    • D
      David MartinAug 28, 2025
      If handset No 1 is sometimes dialled when dialling another handset on your ELFON Intercom System, change the handset No 1 addressing to another number.
  • A
    Andrew WaltersSep 1, 2025
    Why does my ELFON OPTIMA SL255 panel display 'TRY AGAIN' in multi-entry mode?
    • C
      Christine BarronSep 1, 2025
      If the ELFON Intercom System panel displays the message "TRY AGAIN" during each handset dialling attempt in a multi-entry system, ensure that each panel operating in the system has the same option selected - Multi-entry mode ("Two panels" or "OP- H4 mode"). Check the connection of each panel using the Communication test option. If using „OP-H4 mode”, verify that the communication module channels to which the panels are connected are activated. If using „OP-H4MS mode”, ensure one panel is connected to channel 0 of module OP-H4. Also, check if the panel data lines are connected with correct polarization.
  • E
    Edward RobinsonSep 4, 2025
    Why does my ELFON OPTIMA SL255 say 'NUMBER NOT FOUND'?
    • J
      Janet CollinsSep 4, 2025
      If, after selecting a flat number, the ELFON Intercom System panel displays the message "NUMBER NOT FOUND", it indicates that the selected number has not been added to the operated ranges.
  • G
    graychristineSep 8, 2025
    Why does my ELFON Intercom System panel return to the main message after selecting a flat?
    • B
      brianmckeeSep 8, 2025
      If, after selecting a flat, the ELFON Intercom System panel immediately returns to the main message, it is because zero dialling time in general settings, zero ringing time in individual settings, or zero ringing time for the dialled physical number of the handset in individual settings is set.

Summary

General Information

Panel Options Overview

Overview of different OPTIMA series panel models and their features.

Technical Data

Installation Manual

Panel Installation and Supply

Instructions for mounting the panel and connecting its power supply.

Panel Terminals and Audio Installation

Explains panel terminals and guides audio system handset connection.

Video System Installation

Instructions for setting up video systems with monitors and distributors.

Replacing Address Tag

Procedure for replacing the address tag on the entry panel.

Operation and Programming Manual

Keyboard Functions

Explains key functions in normal and menu operation modes.

Initial Start-up Procedure

Steps for initial panel setup, calibration, and potentiometer adjustment.

Establishing a Connection

Guide on how to initiate a call or connection with a specific flat or handset.

Opening the Electric Lock

Various methods to unlock the electric lock using codes, tags, or buttons.

Menu Settings

5.1 Service Programs

Access to diagnostic tests, firmware version, and system setup.

5.1.1 Flats Numeration Configuration

Options for numbering and assigning flats to specific handsets.

5.1.2 Service Tests Overview

Includes tests for picked up handsets and wrong polarization.

5.1.3 Activate Installation Mode and Firmware

Activate installation mode for testing and check firmware version.

5.2 Access Control Settings

Manage service codes, RFID tags, and access control.

5.2.3 Check RFID Tags

Verifies RFID tag status and its assignment within the system.

5.2.4 Serial Number Display

Shows the panel's unique serial number for identification.

5.2.5 RFID Tuning

Adjusts the sensitivity and performance of the RF reader module.

5.2.6 Change General Code Table

Assigns new general opening codes based on the panel serial number.

5.2.7 Change Individual Code Table

Assigns new individual opening codes based on the panel serial number.

5.3 Default Settings Restoration

Resets general system, individual user, and default code settings to factory defaults.

5.3.5 Memory Deletion (RF Tags, Individual Codes)

Clears stored RFID tags and individual access codes from memory.

5.3.7 Default All Settings

Resets all panel configurations back to their factory default state.

5.4 General Settings

Configures parameters like talking time, dialling time, and ringing time.

5.4.2 Electric Lock Settings

Configures electric lock buzz, magnetic mode, and unlocking duration.

5.4.3 Relay Settings

Synchronizes relay settings with electric lock settings.

5.5 Individual Settings

Configures ring tone, loudness, and ringing time for handsets.

5.5.2 Electric Lock Unlocking

Sets handset as door ring and enables electric lock unlocking via handset/RF tag.

5.5.3 Relay Activation

Confirms wrong codes, activates relay, and configures entry codes.

5.5.4 Entry Code Configuration

Manages RF tags, handset power, and office mode activation.

5.6 Enable;Disable Edition

Administrator controls user editing rights for various parameters.

5.6.8 All Parameters Edition Control (Enable;Disable All)

Enables or disables user editing for all system parameters.

Operation in Multi-Entry System

Two-Entry Audio System Configuration

Details on setting up two-entry audio systems and data line connections.

Multi-Entry Video System

Details on additional elements for multi-entry video systems.

Safety Principles

Troubleshooting

ELFON OPTIMA SL255 Specifications

General IconGeneral
ColorWhite
DisplayLCD
Operating Voltage12V DC
Operating Temperature-10°C to +50°C
MaterialPlastic
TypeVideo Intercom System