On the screen there would be prompt “Current, and changeable parameter. By pressing 7 or 9 buttons,
user can change adjustment of RFID parameter, in range from -32 to 32. Adjustment step is 4. To apply new
value of parameter, press “ button, and then program starts testing the new value (message TEST”). To
test the new value, just approach RF tag near the reader. After the test, device will prompt message
APPLY, and press “ ” button to apply new value, or press „#” to get back to RFID tuning.
5.2.6 Change general code table
Allows entering other code table number that this would result from the serial number (e.g. when the old
panel has been damaged or stolen, it is not necessary to pass new codes to tenants, and only enter in the
new panel the table number resulting from the old panel serial number).
§ Enter the menu Settings ( code )
§ Select Default settings (confirm with „ ” )
§ Select Change the individual codes table (confirm with )
§ Current table number will be displayed (confirm with )
§ Enter the selected number and confirm with
§ Confirm with
§ Confirm again with „
Using this function, new general opening codes will be generated: general and individual, according to the
given table number.
5.2.7 Change individual code table
Allows entering other code table number that this would result from the serial number (e.g. when the old
panel has been damaged or stolen, it is not necessary to pass new codes to tenants, and only enter in the
new panel the table number resulting from the old panel serial number).
§ Enter the menu Settings ( code )
§ Select Default settings (confirm with „ ” )
§ Select Change the individual codes table (confirm with )
§ Current table number will be displayed (confirm with )
§ Enter the selected number and confirm with
§ Confirm with
§ Confirm again with „
Using this function, new individual opening codes will be generated: general and individual, according to
the given table number.
5.3 Default settings
!
When restoring default settings, pay particular attention, because previous settings will be
lost for ever.
5.3.1 Default numeration
Restores factory flats numeration method together with full range.
§ Enter the menu Settings ( code )
§ Select Default settings (confirm with „ ” )