Digital Output: ID961: 1 Compressor relay: IEC 60730-1 15(2)A max 250Va
UL60730 1 Hp (8FLA - 48LRA) max 240Va
ID971: 1 Defrost relay: N.O. 8(3)A - N.C. 6(3)A max 250Va
1 Compressor relay: IEC 60730-1 15(2)A max 250Va
UL60730 1 Hp (8FLA - 48LRA) max 240Va
ID974: 1 Defrost relay: N.O. 8(3)A - N.C. 6(3)A max 250Va
1 Compressor relay: IEC 60730-1 8(3)A max 250Va
UL60730 1/2 Hp (5FLA - 29LRA) max 240Va
1 Fan relay: 5(2)A max 250Va
Regulations
Electromagnetic compatibility: This device complies with Directive 2004/108/EC and the harmonised standard EN 60730-2-9
Security: This device complies with Directive 2006/95/EC and the harmonised standard EN 60730-2-9
Food safety: This device complies with standard EN 13485 as follows:
- suitable for storage
- climate range A
- measurement class 1 in the range from -35°C to 25°C (*)
(* exclusively using Eliwell NTC probes)
Voluntary marks/certifications: ENEC/UL (check on the device label).
Classification: operating (not safety) device for integration.
NOTE 1: switch the device off and on after modifying the NTC/PTC probe (par. H00).
NOTE 2: check the power supply specified on the instrument label; for relay and power supply capacities,
contact the Sales Office.
NOTE: The technical data included in this document, related to measurement (range, accuracy, resolution, etc.) refer to
the instrument itself, and not to its equipment such as, for example, sensors.
This means, for example, that sensor(s) error(s) shall be added to the instrument’s one.