ACCESSING AND USING THE MENUS
Resources are organised into menus which are accessed by briefly tapping the key (‘Basic Commands’ menu) or by
keeping the key pressed for more than 5 seconds (‘Programming’ menu).
Either do not press any keys for 15 seconds (time-out) or press the key once, to confirm the last value displayed
and return to the previous screen.
BASIC COMMANDS MENU
Access the ‘Basic Commands’ menu by pressing and releasing the key. If no alarms are active, the ‘SEt’ label appears.
By pressing the and keys you can scroll all folders in the ‘Basic Commands’ menu:
- AL: alarms folder (only visible if an alarm is active);
- SEt: Set point setting folder.
- Pb1: probe 1 folder;
- Pb2: probe 2 folder **;
- dit: interval between defrosts folder;
- dEt: defrost timeout folder;
- dSt: defrost end temperature folder **;
(** models ID971 and ID974 only)
Setting the Set point: To display the Set point value press the key when the ‘SEt’ label is displayed.
The Set point value appears on the display. To change the Set point value, press the and
keys within 15 seconds. Press to confirm the modification.
Change the value of the dit, dEt and dSt defrost parameters in the same way.
Displaying the probes: When the Pb1 or Pb2* label is displayed, press and the associated probe value will appear
(* Pb2 is only present on models ID971 and ID974).
set
set
set
set
6
set
set
set
set
set
set