EasyManuals Logo

Eliwell IDplus 961 User Manual

Eliwell IDplus 961
27 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
TABLE OF PARAMETERS
PAR. DESCRIPTION
SEt Temperature SEtpoint.
COMPRESSOR REGULATOR (folder with “CP” label)
diF diFferential. Relay compressor tripping differential. The compressor stops on reaching the Setpoint value (as
indicated by the adjustment probe), and restarts at temperature value equal to the Setpoint plus the value
of the differential. Note: the value 0 cannot be assumed.
HSE Higher SEt. Maximum possible setpoint value.
LSE Lower SEt. Minimum possible setpoint value.
OSP Offset Set Point. Temperature Value to be added to the Set-Point if reduced set is enabled (Economy function).
dOd digital (input) Open door. Digital input that allow you to switch off loads. Valid if H11 = ±4 (door microswitch).
n = does not switch off loads; y = switch off loads
COMPRESSOR PROTECTIVE DEVICE (folder with “CP” label)
Ont On time (compressor). Compressor activation time in the event of faulty probe. If Ont=0 the compressor is
always off, while Ont>0 the compressor is always on.
dOn delay (at) On compressor. Delay time in activating the compressor relay after switch-on of instrument.
dOF delay (after power) OFF. Delay after switch off; the indicated time must elapse between switch-off of the
compressor relay and the successive switch-on.
dbi delay between power-on. Delay between switch-ons; the indicated time must elapse between two successive
switch-ons of the compressor.
OdO (!) delay Output (from power) On. Delay time in activating the outputs after switch-on of the instrument or after
a power failure.
DEFROSTING REGULATOR (folder with “dEF” label)
dty defrost type. Type of defrosting.
0 = electric defrost - compressor off (OFF) during defrosting;
1 = reverse cycle defrost (hot gas); compressor on (ON) during defrosting;
2 = Free defrost; defrosting independently of compressor.
16