Smart ZB Thermostat 16 A
Setting and operating the device manually
As a standalone thermostat, you can set the following settings and operating parameters.
Preset
Sensor
type
selection
Floor
calibration
setting
Max
guard
temp.
setting
Boost
mode
Standalone
schedule
P1
x x x
� �
P2
x x x
� �
P3
x x x
� �
P4
x x x
� �
P5
x x x
� �
P6
� � � � �
P7
� � � � �
P8
� � � � �
P9
x x x
� �
Sensor type selection, page 10
Floor calibration setting, page 10
Max guard temp. setting, page 10
Boost mode, page 12
Device presetting
You can preset the thermostat on the first power-on or immediately after a factory
reset. The thermostat will require the selection of a preset to pre-configure settings
depending on what the thermostat is directly controlling, which allows the
thermostat to function correctly for the intended use case. Preset selection is a
manual process and all preset uses a PI control algorithm which provides highly
stable results.
You can choose one preset configuration:
Preset
Configuration
Control type / Set
point range
Cycle time* (min)
P1
Heat Pump/Oil Boiler
Room Control
4°C ~ 30°C
20
P2
Hydronic Radiator/Gas Boiler
10
P3
Hydronic Underfloor
10
P4 Electrical Radiator 10
P5
Electrical Underfloor (Without
floor limits)
10
P6
Electrical Underfloor (With floor
limits)
10
P7
Hydronic Underfloor
Floor Control
10°C ~ 40°C
10
P8 Electrical Underfloor 10
P9
Regulator Mode (output
displayed is based on
percentage)
Floor Control
0 ~ 10 (0% ~ 100%)
30
*Cycle time: This setting determines the length of each on/off cycle of the output
relay. The percentage of time within that cycle time that the relay is on is varied
based on demand. A longer cycle time may be more appropriate for slow heating
DUG_ZB Thermostat 16 A_ELKO-00 7