Smart ZB Thermostat 16 A
Manual sensor settings
A thermostat with a preset value of P6 to P8 can be connected with an external
floor sensor to increase the user's experience in regulating the temperature.
NOTE: Once the preset is chosen, press O button for 1 second to confirm.
Then the device continues to the sensor setting in the below sequence. For
more info on preset, refer device presetting, page 7
Selecting floor sensor type
After preset, you will enter floor sensor selection menu where you can manually
select the sensor type connected to the thermostat after setting the preset; this
allows the thermostat to convert and display the temperature accurately.
To select the floor sensor type:
1. Once you enter the selection menu, “10” will be displayed on the thermostat
dot matrix. Press + or touch button on the device to switch between the
sensor types.
Following are the available sensor type:
10 kOhm
12 kOhm
15 kOhm
33 kOhm
47 kOhm
TIP: When + button is pressed, sensor type 10 becomes 12, continue to
press the + button, and the type changes to 15, 33, and 47.
When button is pressed, sensor type 47 becomes 33, continue to press
the button, and the type changes to 15, 12, and 10.
2. Select the sensor type which is installed and then press the O touch button for
> 1 s to confirm the selection.
The thermostat dot-matrix display the sensor type and
LED flashes blue.