Smart ZB Thermostat 16 A
Manual sensor settings
A thermostat with a preset value of P6 to P8 can be connected with an external
floor sensor to increase the user's experience in regulating the temperature.
NOTE: Once the preset is chosen, press O button for 1 second to confirm.
Then the device continues to the sensor setting in the below sequence. For
more info on preset, refer device presetting, page 7
Selecting floor sensor type
After preset, you will enter floor sensor selection menu where you can manually
select the sensor type connected to the thermostat after setting the preset; this
allows the thermostat to convert and display the temperature accurately.
To select the floor sensor type:
1. Once you enter the selection menu, “10” will be displayed on the thermostat
dot matrix. Press + or – touch button on the device to switch between the
sensor types.
Following are the available sensor type:
• 10 kOhm
• 12 kOhm
• 15 kOhm
• 33 kOhm
• 47 kOhm
TIP: When + button is pressed, sensor type 10 becomes 12, continue to
press the + button, and the type changes to 15, 33, and 47.
When – button is pressed, sensor type 47 becomes 33, continue to press
the – button, and the type changes to 15, 12, and 10.
2. Select the sensor type which is installed and then press the O touch button for
> 1 s to confirm the selection.
The thermostat dot-matrix display the sensor type and
LED flashes blue.
10 DUG_ZB Thermostat 16 A_ELKO-00