Page #44 background imageLoading...
Page #44 background image
ENGLISH
ABOUT
RS-232C
97
Data Format Specification
This command is executed in the form of 1-command/1-packet. The next command is not
accepted until the previous processing is completed.
The communication command always starts with STX (Start of Text), and ends with ETX (End
of Text).
If the communication format of command name is wrong, NAK (Negative Acknowledge)
will be sent from this product as a result of failing to receive correctly.
When communication format is received correctly, this product sends ACK (Normal
Acknowledge).
Operation Command (PC This product)
Each operation command is executed in ASCII code, and transmitted in a set of 7 bytes as
follows:
Response Data Format (This product PC)
All response data is transmitted as ASCII code, corresponding to the parameters in the
operation command table.
Status 0
Status 2
ROM Ver0 (SUB)
ROM Ver1 (MAIN) . . . Upper 6 bytes
ROM Ver 2 (MAIN) . . . Lower 4 bytes
S
T
X
E
T
X
Command
(PC)
(This product) ACK
Data
Parameter
S
T
X
Posi/
Nega
Color/
B&W
Display
Camera
mode
/SD mode
Local
lockout
E
T
X
Input
selection
Lighting
ON/OFF
Pause
Gamma
selection
Monitor
output
S
T
X
Image
rotation
Edge
effect
White
balance
Text
USB
mode
E
T
X
AUTO:31H
MANUAL:32H
Iris
mode
V
56H
H
48H
L
4CH
B
42H
S
T
X
E
T
X
20H
S
T
X
E
T
X
B
42H
S
T
X
E
T
X