1.3 Functional principle
The Safety evaluation unit monitors connected sensors that are equipped
with a NO contact and NC contact. The switching sequence of the contacts
does not matter.
The Safety evaluation unit switches a safety output in accordance with the
operating statuses of the connected sensors and the connected external
contactors.
In the following situations, the Safety evaluation unit switches off the safety
output:
• The sensors are correctly actuated.
• The feedback contacts of the external contactors are closed.
In the following situations, the safety evaluation unit switches off the safety
output:
• An NO contact of a connected sensor is open.
• An NC contact of a connected sensor is closed.
• A fault is pending (the safety evaluation unit or a connected sensor is de-
fective).
1.3.1 Intended use
The safety evaluation unit is part of the overall system or machine and is for
the purpose of assuming safety-related functions. In order to do so, the sys-
tem monitors signals from magnetic safety sensors. This means that the out-
put is opened or closed depending on the status of the safety sensors.
The product must be used only in accordance with the descriptions below
for protection against dangers.