EasyManua.ls Logo

ELTEX KNH35 - 7. Troubleshooting

ELTEX KNH35
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
40 BA-en-3031-2004_KNH35
7. Troubleshooting
Warning!
Electric shock hazard!
Do not carry out any maintenance or repair work without first switching
off the high voltage and disconnecting the supply voltage.
The machine which has the charging bars fitted must not be in opera-
tion.
Any work involving the units must be carried out by qualified electri-
cians.
Error messages
Defect/Error Defect/Cause Remedy
Generator cannot be
switched on
Defective fuse.
Supply voltage not
connected.
Replace fuse, (see name plate).
Connect or activate supply voltage.
Error text:
01 limiter
Limiter set for <switch off>,
selected value is exceeded.
Investigate cause why limit value was
exceeded!
If necessary, increase limit value.
Error text:
02 spark counter 1
5 high-power discharges
within <5 seconds.
Reduce output voltage.
Clean bars
(see Maintenance).
Error text:
03 spark counter 2
Processor measuring range
was exceeded.
Reduce output voltage.
Clean bars
(see Maintenance).
Check high voltage cables.
Error text:
04 short-circuit
Short-circuit detected
(with a current of >5 mA and
a voltage of <150 V).
Disconnect connected consumers one
after the other and localize the short-
circuit.
Error text:
05 no voltage
Error in high voltage
generation.
Acknowledge error, if it recurs, send unit
for repairs.
Error text:
11 calibration
Defective or no calibration
data in EEPROM.
Memory problem, send unit for repairs.
Error text:
12 EEPROM error
Error in EEPROM. Switch appliance off and back on. If error
recurs, a memory problem exists, send
unit for repairs.
Error text:
13 +13 V missing
Acknowledge error, if it recurs, send unit
for repairs.
Error text:
14 –12 V missing
Acknowledge error, if it recurs, send unit
for repairs.

Related product manuals