IT
24
40540 - 40542 - 40540.D - 40547
Secondary identification code programming
Programming of the secondary identification code is only required when more than one entryphone is to be called
simultaneously using the same push button or call code. The entryphones that are to ring simultaneously must be
associated with the same group. The “master” entryphone is programmed first by means of the “identification code
programming” procedure described above, while the additional group entryphones are programmed with the secondary
identification code. The maximum number of entryphones that can be associated with the same group without using a
SaveProg software is 3 plus a master unit.
Programming phase:
1. In the case of a handset entryphone, raise the handset and bring it to your ear to listen to the sound feedback emitted
by the handset during the programming phase.
2. Press and hold down the lock push button “
” for 6 s.
3. When the time runs out the indoor station will emit a “beep” (0.5 s).
4. Continue holding down the lock push button “
”.
5. After 2 s more the indoor station emits two “beep” in sequence apart (duration 0.5 s).
6. Release the lock push button “
”. When the push button is released the communication will be signalled by a “beep”
with a different frequency.
7. On push button entrance panels, press the call button for the “master unit” entryphone, while entrance panels with
alphanumeric keypads, enter the call code and the call button to confirm (
or , depending on the entrance panel
model).
If the unit has been programmed correctly you will hear a tone, otherwise repeat the programming sequence.
beep1
BEEP
BEEP
1
beep
2
2a
43 5
beep2
> 6 s + 2 s
> 6s
beep1
BEEP
BEEP
beep
2
2a
43 5
+ 2 s
beep2