CHAPTER 2. TECHNICAL SPECIFICATIONS 15
2.4 Information about input inrush current
Inrush Specications
Allowed inrush events 1 per day
Inrush current (cold state) 235 A peak
Inrush current (hot state) 357 A peak
Input fuse melting (i²t) 209 A²s
Inrush current refers to a transient phenomenon that occurs rarely and only when
the power supply cord is connected to the power grid or in the case of power grid
shutdown. CF10C inverter series are designed accordingly and can reliably with-
stand this current along the expected product lifespan. Excessive inrush current
events may damage the inverter. Regarding inverter installation, Embraco recom-
mends to have the appliance supply cord directly connected to inverter power input
without any disconnection means. Please, contact Embraco Technical Support for
any assistance or application assessment needed.