CHAPTER 3. INSTALLATION 19
3.1.2 VNE compressor cable connection
To connect the inverter to the compressor, attach the motor cable on the hermetic
compressor terminal, as shown in the sequence
*
.
11
2.7. Electrical components installation
Step 1:
Check the cord anchorage position on
the fence support (1).
Step 3:
Grounding terminal to fasten the
screw in cord anchorage bracket (3)
(screw torque 0.1 - 0.6 N.m.).
Step 4:
Insert OLP bracket in the hermetic
terminal pin (4).
Step 2:
Slide cord anchorage snap for
attachment on fence (2).
2
3
4
1
*
The gures displayed here are merely illustrative