EMCS User Guide
- 18 -
6.2.12
Command # 23: RING PHONE EXTENSION
This command enables signaling from the Consolidator to on-site remote locations.
When turned on, remote phones attached to the MR terminal will ring and display
emergency call and alarm status information on the CID screen.
Voice Prompt: Ring phone extension
6.2.13
Command # 24: CALLER ID UPDATE TIMER
Alarm status information is displayed on every on-site remote phone CID screen and
updated at intervals defined by this timer (in minutes).
Voice Prompt: “Caller ID update timer”
6.2.14
Command # 25: START PLM TEST
To simulate a cab phone failure, set the PLM test on the EMC-60 cab phone
(Command 24) to 1 - 100s, which de-energize the PLM alarm relay for the time
selected. Start the EMCS PLM test (touch 1 to confirm) to activate the alarm.
The EMCS will check the status every minute until the EMC-60 PLM alarm resets.
Voice Prompt: “PLM test
6.2.15
Command # 26: PLM CHECK INTERVAL
The ‘PLM Check Interval’ sets the test frequency (Code requires at least once per day)
When PLM Check Interval = 0, the EMCS executes a full PLM check every 12 hours.
When PLM Check Interval = 1, the EMCS executes a full PLM check every 5 hours.
Voice Prompt: “PLM check interval