1.1 Key Features
ASME A17.1/CSA B44 Safety Code for Elevators requires the means to call into
any elevator from within a tall building with elevator travel greater than 60’ (18m).
The EMCS Consolidator manages this operation through its handset and any
connected remote handsets, overriding off-site calls in progress.
Intuitive visual and audible indications for system operation and call routing
- Colour-coded touch-control icons indicate each elevator phone status
- Voice prompts announce current system status to any handset away from
the main display, either on-site or off-site, with on-site CID display
System-wide page (ALL CALL) from on- or off-site to all elevators
2 concurrent calls to reduce wait time in a broad emergency
Ease of setup and operation
- "Learn" mode to automatically configure the system
- Programmable Phone Line Monitoring (PLM) group configuration
- “Line Test” mode to assess the building phone line
- Remote phones can call off-site
- Bilingual voice prompts
- Touch keypad (French overlay available)
Advanced diagnostics
- Built-in Phone Line Monitoring (PLM) from each elevator to the EMCS and
for each connected TEL line as required by Code
- Watchdogs with counters for automatic fault recovery and reporting
- Remotely simulate alarm call
3 PLM group alarm relays for every 6 cabs (fail safe - closed when no alarm)
Built-in Video Trigger relay per elevator (normally open) plus all-clear signal
“Call Anywhere” (see Call Routes Available on page 2)
Call off-site, via an available phone line, using any on-site phone
Simple SD card firmware upgrades enable feature flexibility with optional
customization
Digital chip platform
Self-diagnostics continuously monitor its own operation and its environment
Compatible with a wide range of power supply voltages (AC and DC)
Vandal-resistant #16-AWG Brushed Stainless Steel
Box width 14.25" to fit (recess) between wall studs
Status and alarm messages displayed on Remote Phone CID