7.2.6 Europe
N1 ATEX Increased Safety with Intrinsically Safe Outputs to Zone 0
Certificate
SGS20ATEX0036X
Markings
II 3(1)G Ex ec [ia Ga] IIC T4 Gc (-40 °C ≤ T
a
≤ +65 °C)
Standards
EN IEC 60079-0: 2018, EN IEC 60079-7:2015+A1:2018, EN
60079-11: 2012, EN 60079-15:2010, EN 60079-31:2014
N1 ATEX Increased Safety with Intrinsically Safe Outputs to Zone 0 (For
use only with the Cisco Outdoor Access Point Model IW-6300H-AC-x-K9)
Certificate
SGS20ATEX0036X
Markings
II 3(1)G Ex ec nA [ia Ga] IIC T4 Gc (-40 °C ≤ T
a
≤ +65 °C)
Standards
EN IEC 60079-0: 2018, EN IEC 60079-7:2015+A1:2018, EN
60079-11: 2012, EN 60079-15:2010, EN 60079-31:2014
Special Conditions for Safe Use (X):
1. The enclosure’s polyurethane paint finish may constitute an
electrostatic hazard. Care should be taken to protect it from external
conditions conducive to the build-up of electrostatic charge on such
surfaces. The equipment must only be cleaned with a damp cloth.
2. The equipment is not capable of withstanding the 500V electrical
strength test as defined in clause 6.1 of EN 60079-7:2015+ A1:2018
and 6.3.13 EN 60079-11:2012. This must be taken into account
during installation.
N1 ATEX Increased Safety with Intrinsically Safe Outputs to Zone 2
Certificate
SGS20ATEX0057X
Markings
II 3G Ex ec [ic] IIC T4 Gc (-40 °C ≤ T
a
≤ +65 °C)
Standards
EN IEC 60079-0: 2018, EN IEC 60079-7:2015+A1:2018, EN
60079-11: 2012, EN 60079-15:2010, EN 60079-31:2014
N1 ATEX Increased Safety with Intrinsically Safe Outputs to Zone 2 (For
use only with the Cisco Outdoor Access Point Model IW-6300H-AC-x-K9)
Certificate
SGS20ATEX0057X
Markings
II 3G Ex ec nA [ic] IIC T4 Gc (-40 °C ≤ T
a
≤ +65 °C)
Standards
EN IEC 60079-0: 2018, EN IEC 60079-7:2015+A1:2018, EN
60079-11: 2012, EN 60079-15:2010, EN 60079-31:2014
July 2022 Quick Start Guide