EasyManua.ls Logo

Emerson 2404 - 10.5 Menu 4: Current control

Emerson 2404
200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Introduction
Parameter
x.00
Parameter
description format
Keypad and
display
Serial
communications
CT Modbus
RTU
PLC Ladder
programming
CTSoft Menu 0
Advanced parameter
descriptions
Menu 4
Commander SK Advanced User Guide 61
Issue Number: 9 www.controltechniques.com
10.5 Menu 4: Current control
Table 10-6 Menu 4 parameters: single line descriptions
Parameter Range Default Setting Update Rate
4.01 Current magnitude (motor current) {88}
0 to
DRIVE_CURRENT_MAX A
B
4.02 Motor active current
{89) ±DRIVE_CURRENT_MAX
A
B
4.03 Not used
4.04 Current demand
± TORQUE_PROD_
CURRENT_MAX%
B
4.05 Not used
4.06 Not used
4.07 Symmetrical current limit
0 to
MOTOR1_CURRENT_LIMI
T_MAX %
165.0 B
4.08 Torque reference
± USER_CURRENT_
MAX%
0.0 B
4.09 Not used
4.10 Not used
4.11 Torque mode selector OFF(0) or On(1) OFF(0) B
4.12 Not used
4.13 Current controller Kp gain 0 to 250 20 B
4.14 Current controller Ki gain 0 to 250 40 B
4.15 Motor thermal time constant 0 to 250 89 B
4.16 Motor thermal protection mode OFF(0) or On(1) OFF(0) B
4.17 Reactive current
±DRIVE_CURRENT_MAX
A
B
4.18 Overriding current limit
0.0 to TORQUE_PROD_
CURRENT_MAX%
B
4.19 Motor overload accumulator 0.0 to 100.0%
B
4.20 Percentage load
± USER_CURRENT_
MAX%
B
4.21 Load display units {22} Ld(0) or A(1) Ld(0) B
4.22 Not used
4.23 Not used
4.24 User current maximum scaling
0.0 to TORQUE_PROD_
CURRENT_MAX%
165.0 B
4.25 Low speed thermal protection mode OFF(0) or On(1) OFF(0) B
4.26 Percentage torque
± USER_CURRENT_
MAX%
B
4.27 Reduce internal current loop response OFF (0) or On (1) OFF(0) B

Table of Contents