80 Series Thermostats
29
Application Selection Jumpers
Conventional & Universal Models
RC / RH Jumper
Single Transformer Systems Don’t
Clip Jumper
The thermostat electrically connects the
RC (Hot Leg of the Cooling Transformer)
and the RH (Hot Leg of the Heating
Transformer) so a jumper is not required
Two Transformer Systems Clip
Jumper
If there is a separate wire for RC and RH,
clip the RC/RH jumper on the back of the
thermostat.
This will isolate both terminals so they can
be independently used.
Heat Pump Models
W2 / E Jumper
Combined Aux and Emergency Heat
Don’t Clip Jumper
The Heat Pump thermostat electrically
connects W2 and E terminals so you do not
need to install a jumper wire.
Independent Aux and Emergency Heat
Clip Jumper
If there are separate W2 and E wires, clip the
W2/E jumper located on the back of the
thermostat.
Setting system switch to Aux results in
auxiliary heating with no compressor
operation.
For Two Transformer Systems, improper phasing will result in damage to the transformer.