80 Series Thermostats
40
Heat Pump Models - 2H/1C Wiring
• Staging
– Heat Pump thermostats call 1st stage compressor with a 2nd stage of auxiliary
• Auxiliary Selection
– Aux Heat as 2nd stage only with one wire to W2
– Independent Auxiliary System Switch Selection (2 wires to W2 and E)
• For separate W2 and E wires, clip the W2/E jumper located on the back of the thermostats.
• Wire W2 & E separately so the compressor does not turn on when system switch is set to Aux
• Dual Fuel is selected in the Installer’s Menu, Item 60
Heat Pump 2 Heat / 1 Cool
Heat Pump
Staged
R O/B G Y E W2 C L
Power
(24V)
Reversing
Valve
Fan
Relay
1
st
stage
compressor
2
nd
Stage
Heat
(Aux)
Common
wire for
24C
Heat Pump
Malfunction/
Diagnostics
Terminal
(input signal
requires
common)
Heat Pump
with
Separate
Aux or (Dual
Fuel)
Emer.
Heat
Only
R O/B G Y E W2 C L