Procedure
1.
From the Laser Align Application main menu, press ALT > F9 Job Manager.
The Job Manager screen is displayed.
2. Press F10 or F11 to select the job you want to activate and press F9 Activate
Job.
The Laser Align Application main menu is then displayed. It is where you
can begin the three-step alignment process and store data in the active
alignment job.
3.3 Set the job parameters
This document only covers some of the job parameters you can set up for a
horizontal alignment job. Refer to the Alignment chapter of the AMS 2140
Machinery Health Analyzer User Guide for more information on the other job
parameters you can set.
3.3.1 Set the job mode
Horizontal alignment is available in Basic and Advanced mode.
Procedure
1. Activate or create a horizontal alignment job.
For newly created jobs, the job mode is set to Advanced by default.
2. From the Laser Align Application main menu, press ALT > F2 Job Mode.
Pressing this key toggles between Advanced and Basic modes.
3. Press Yes to proceed with the job mode change.
CAUTION!
Changing the job mode clears all data previously acquired for the job.
3.3.2 Change the machine configuration
Change the machine configuration on the AMS 2140 to reflect your current
machine setup.
Procedure
1. Activate a horizontal alignment job.
2. From the Laser Align Application main menu, press ALT > F3 Machine
Config.
December 2018 Quick Start Guide
Quick Start Guide 17