Fig.12: Blocking of base plates and valve driver boards
(1) Valve position 1 (2) Valve position 2
(3) Valve position 3 (4) Valve position 4
20 Base plate, 2x 22 Valve driver board, 2x
36 Right plug 37 Left plug
The following valve driver and supply boards are present:
UA
22
23
24
38
35
Fig.13: Overview of the valve driver and supply boards
22 Valve driver board, 2x 23 Valve driver board, 3x
24 Valve driver board, 4x 35 Electrical supply plate
38 Supply board
Electrical supply plates can be used to separate the valve system into sections
with different voltage zones. For this purpose, the supply board interrupts the
24V and the 0Vlines from UA voltage in the backplane. A maximum of ten volt-
age zones are permitted.
The power supply to the electrical supply plate must be taken into ac-
count during PLC configuration.
12.2.6 Pressure regulators
You can use electronically operated pressure regulators as a pressure zone con-
trol or single pressure control depending on the selected base plate.
Fig.14: Base plate for pressure regulators for pressure zone control (left) and sin-
gle pressure control (right)
39 AV-EP base plate for pressure zone
control
40 AV-EP base plate for single pressure
control
41 Integrated AV-EP circuit board 42 Valve position for pressure regulator
Pressure regulators for pressure zone control and single pressure con-
trol do not differ in terms of the electronic control. This is why the dif-
ferences between the two AV-EP pressure regulators are not discussed
in further detail here. The pneumatic functions are described in the op-
erating instructions for AV-EP pressure regulators, which can be found
on CDR412018133.
12.2.7 Bridge cards
Fig.15: Bridge cards and UA-OFF monitoring board
28 Bus coupler 38 Transition plate
29 Pneumatic supply plate 43 Electrical supply plate
30 Supply board 44 Long bridge card
35 Short bridge card 45 UA-OFF monitoring board
Bridge cards have the sole function of bridging the pressure supply areas. They
are therefore not taken into account during PLC configuration.
Bridge cards are available in long and short versions:
The long bridge card is always located directly on the bus coupler. It bridges the
transition plate and the first pneumatic supply plate.
The short bridge card is used to bridge additional pneumatic supply plates.
12.2.8 UA-OFF monitoring board
The UA-OFF monitoring board is an alternative to the short bridge card in the
pneumatic supply plate (see Fig.14).
The electrical UA-OFF monitoring board monitors the actuator voltage UA for sta-
tus UA<UA-OFF. All voltages are passed through directly. The UA-OFF monitor-
ing board must therefore always be installed after an electrical supply plate to be
monitored.